Chapter 2. Normal Operation
PELLERIN MILNOR CORPORATION
Chapter 2
Normal Operation
BICEUO03 (Published) Book specs- Dates: 20080219 / 20080219 / 20080219 Lang: ENG01 Applic: CEU
2.1. E-P OneTouch
®
Operation
2.1.1. Instructions for Normal Operation
2.1.1.1. Load the Machine
1. If the loading door is closed and latched, hold the Door Unlock button (
'
) to unlock the door
while operating the door latch with the other hand. If the door does not unlock, verify that the
machine is connected to power and that the wall disconnect is functioning properly. The
machine must have power available to unlock the door.
2. When the door opens, load the machine according to plant guidelines and Section 2.2.
“Determining Load Size”.
3. Close the door firmly.
2.1.1.2. Start a Formula
2.1.1.2.1. After a Completed Formula (Normal)—If the previous formula finished normally, simply
press the button that matches the formula you want to run. The selected formula will start
immediately if the door is closed. The Formula Running light (
\
) illuminates and the door locks
immediately, and the machine fills with water. Once the door is locked, the operator must end the
formula early (see Section 2.1.2) or wait for the formula to finish before opening the door.
2.1.1.2.2. After Opening the Door during a Formula—If you ended the previous formula early by
opening the door, you must press the Terminate button (
z
) before you can start the machine again.
The Terminate button also clears any internal machine error that might have caused the formula to
end early.
2.1.1.3. Unload the Machine—When the formula ends, the Formula Running light (
\
) goes out.
Hold the Door Unlock button (
'
) to unlock the door while operating the door latch with the othe
r
hand.
2.1.2. How to End a Formula Early
You can end any running formula by pressing the Terminate button (
z
) on the control panel. A
safety delay keeps the door locked for 75 seconds. When the In Progress light goes off, hold the
Door Unlock button (
'
) to unlock the door while operating the door latch with the other hand.