Chapter 3. Operating
PELLERIN MILNOR CORPORATION
3.2.2.2.
Terminate
Button
—In normal operation mode, this button terminates the formula in
progress. All controls are immediately locked out for a safety delay of 75 seconds.
In testing mode (DIP switch position 8 is
off
), the
Terminate
button provides input F to the
microprocessor.
3.2.2.3.
Last Rinse
Light
—In normal operation the
Last Rinse
light illuminates constantly from the
beginning of the last bath step (last rinse) until the formula ends, 75 seconds after the end of the
final extract step.
In testing mode (DIP switch position 8 is
off
), the
Last Rinse
light illuminates when output 8
is
on
.
3.2.2.4.
In Progress
Light
—In normal operation with the display attached, this light is illuminated
when output j is present.
Display or Action Explanation
abcdefghijklmnop
--+--+---+------
Typical display during normal operation with the drain closed
(output c), the basket turning clockwise (output f), and the
In
Progress
light illuminated (output j).
In testing mode (DIP switch position 8 is
off
), the
In Progress
light illuminates when output
9 is
on
.
3.2.2.5.
Door Unlock
Button
—In normal operation with the display attached, this button is enabled
75 seconds after a formula ends for any reason. The door cannot be unlocked until the 75-second
safety delay expires. The safety delay also applies for 75 seconds after power is first applied to
the machine.
In testing mode (DIP switch position 8 is
off
), the
Door Unlock
button is energized only
when output 00 is
on
. With output 00
on
, you should hear the door unlock when this button is
pressed.
— End of BICEUF01
Document ............. BICEUO01
S
p
ec Date ................ 2001012
2
3.3. E-timer Operation
As-of Date ............... 2001012
2
3.3.1.
Instructions for Normal Operation
3.3.1.1.
Load the Machine
1. If the loading door is closed and latched, hold the
Door Unlock
button (
'
) to unlock the
door while pressing firmly on the door latch handle with the other hand. If the door does not
unlock, verify that the machine is connected to power and that the wall disconnect is
functioning properly. The machine must have power available to unlock the door.
2. When the door opens, load the machine according to plant guidelines and “Determining Load
Size” (see table of contents).
3. Close the door firmly.