Chapter 3. Operating
PELLERIN MILNOR CORPORATION
3.3.1.2.
Start a Formula
3.3.1.2.1.
After a Completed Formula (Normal)
—If the previous formula finished normally, simply
press the button that matches the formula you want to run. The selected formula will start
immediately if the door is closed. The
Formula Running
light (
\
) illuminates and the door locks
immediately, and the machine fills with water. Once the door is locked, the operator must end the
formula early (see Section 3.3.2) or wait for the formula to finish before opening the door.
3.3.1.2.2.
After Opening the Door during a Formula
—If you ended the previous formula early by
opening the door, you must press the
Terminate
button (
z
) before you can start the machine
again. The
Terminate
button also clears any internal machine error that might have caused the
formula to end early.
3.3.1.3.
Unload the Machine
—When the formula ends, the
Formula Running
light (
\
) goes out.
Hold the
Door Unlock
button (
'
) to unlock the door and press firmly on the door latch handle.
3.3.2.
How to End a Formula Early
You can end any running formula by pressing the
Terminate
button (
z
) on the control
panel. A safety delay keeps the door locked for 75 seconds. When the In Progress light goes off,
hold the
Door Unlock
button (
'
) to unlock the door and press firmly on the door latch handle.
To resume operation, restart the formula from the beginning by pressing the desired formula
button.